Ozone Destructor | ODH Heat Type Ozone Destructor
Working Principle
It adopts ODH high-temperature thermal decomposition method. Ozone is chemically unstable and will decompose into oxygen faster with rising temperature. Ozone starts to decompose at 30°C, and the decomposition rate increases obviously at 50~80°C. At 200°C, the ozone decomposition rate reaches around 80% within 1 minute; at 250°C, the decomposition rate rises to 92%~95%. When the temperature hits 300°C or above, residual ozone can be 100% decomposed with only 1~2 seconds of retention time, without generating secondary pollutants.
Application Fields
Ozone generation system: Supporting ozone off-gas treatment equipment for ozone generators to break down unreacted residual ozone, prevent ozone leakage and comply with environmental discharge regulations.
Industrial wastewater treatment: Ozone tail gas elimination after ozone oxidation process for wastewater, protecting on-site operators.
Pure water & tap water treatment: Ozone off-gas destruction after ozone disinfection for water purification and remove ozone pollution.
Chemical oxidation process: Residual ozone decomposition for chemical ozone catalytic oxidation systems.
Space ozone disinfection: Degrade tail gas after ozone sterilization in food workshops, cold storage and clean workshops.